More room. Same grid.

Unlock More Capacity.
With the Same Grid.

GridFlow develops intelligent demand flexibility software to help data centers, industrial facilities and grid operators anticipate electricity demand, reduce peak loads and make better use of existing grid capacity.

Peak Shaving
Load Shifting
Battery Optimization
Scroll
The peak-demand challenge

Your electricity demand has
a timing problem.

A site peak is the highest power it draws. A connection limit is the power available to that site. Network congestion depends on conditions reported by the grid operator.

PEAK DEMAND
01

Everything starts at once.

Computing, cooling and production can overlap. When demand exceeds available connection capacity, growth and operating schedules can come into conflict.

TIMING
02

Flexibility stays invisible.

Some electricity use can move in time. Without a clear view of the constraints, that potential stays unexplored.

CONNECTION LIMIT
03

Is the shift enough?

A lower peak may still miss a temporary limit. Compare load shifting and battery dispatch against the actual limit entered for each interval before pricing the result.

CAPACITY IS ABOUT TIMING

The same energy. A different demand curve. An opportunity to use existing electrical capacity more intelligently.

Demand flexibility technology

One coordinated approach.
More flexible electricity.

Peak shaving is the goal. Load shifting and batteries are two ways to achieve it. The demo schedules them using physical constraints; future AI forecasting would help anticipate when flexibility is needed.

Peak Shaving. Reduce the highest grid import in kW, within site and equipment constraints.
Load Shifting. Reschedule eligible demand to less constrained intervals while conserving site energy.
Battery Optimization. Schedule charging and discharging to support peak shaving, accounting for power, stored energy and losses.
Technology roadmap
Load shifting and batteries · available in simulation
AnalyzeMap demand, equipment and limits
PredictAI demand forecasting · planned
IdentifySeparate flexible and critical loads
OptimizeShave peaks with shifting and storage
EvaluateCheck power, costs and operations
AnalyzeMap demand, equipment and limits
Roadmap
Built around real electricity use

Different sites.
The same capacity challenge.

We focus on power-intensive facilities and the grid partners that define their operating limits. A pilot tests the value for each site and its connection.

Data Centers

When a power limit constrains growth, test deferrable workloads and battery dispatch to shave grid peaks while protecting critical computing.

Industrial Facilities

When production peaks overlap, test scheduling and storage to reduce peak import and costs while preserving operational continuity.

Grid Operators & Energy Partners

When local capacity is tight, assess available demand flexibility and test coordinated load or storage schedules for flexible connection scenarios.

Seeking pilot partners

Four steps to put your site’s
flexibility to work.

Start with one site, an agreed power limit and a question your operations team wants to measure.

01

Scope

Agree on the capacity limit, the loads to study and what a successful pilot would measure.

02

Model

Use permitted interval data, operating windows and actual tariffs to compare schedules.

03

Validate

Review calculations, remaining exceedance and operational feasibility with qualified engineers and the site team.

04

Pilot

After approval, test on a limited scope and measure the outcome against the baseline.

What a pilot could deliver: a baseline electricity demand profile, a flexibility assessment, alternative schedules, peak reduction and capacity compliance results, a financial comparison, and technical limits and recommendations.
Product capabilities

What you can try today.
What we plan to build.

Explore the current models for peak shaving, load shifting and batteries. Forecasting and live coordination are development goals.

CAPABILITY / 01

Demand Forecasting

Planned AI forecasts would help anticipate high demand from measured site data. No AI forecast is used in the demo.

CAPABILITY / 02

Flexibility Assessment

Estimate the declared load available for shifting after protecting critical use and applying equipment and time limits.

CAPABILITY / 03

Peak Demand Optimization

Compare peak shaving from load shifting, battery dispatch or both, against an unchanged reference.

CAPABILITY / 04

Grid Constraint Management

Test a connection limit and temporary import limits supplied or assumed for one connection. Network studies and coordination require separate validation.

CAPABILITY / 05

Battery Optimization

Schedule charge and discharge within power, capacity and efficiency limits, with the same charge at the end of the day.

CAPABILITY / 06

Economic Analysis

Price the same grid import curves with entered rates, demand charges and costs, whether the result is positive or negative.

Demand flexibility simulator

Reduce peaks.
Work within available capacity.

Compare load shifting and battery dispatch on one representative day. Test your connection limit and any temporary restrictions before looking at costs.

YOUR ELECTRICITY SCENARIO
Operating windows and temporary capacity limits

Flexible equipment operating windows

Only load within these hours can be moved, and only to another allowed interval. No windows means no load shifting.

Operating window 1

Temporary grid restrictions

Enter periods supplied by a grid operator or use explicit scenario assumptions. A site peak is not evidence of congestion. When limits overlap, the lowest applies.

Quarter-hour boundaries, in site-local time. An end earlier than the start runs through midnight.

Battery settings

Final state of charge: 50%, equal to initial charge for a repeatable day. Storage stays within its power and charge limits. Set capacity to zero to test without storage.

A fictional production day with a deferrable process. Production deadlines and critical equipment must be verified on site. Critical demand remains served in every interval. The flexible equipment cap and site grid limit apply to different quantities.

ELECTRICAL RESULTSExample data
Grid import peak reduction42.1%181.03 kW lower
Site connection limit350 kW
Before optimization
79.96 kW maximum exceedance
180 min above applicable limits
Selected scenario
101.07 kW minimum headroom
0 min above applicable limits
Within modelled capacity limits
Initial peak demand429.96 kW
Selected peak demand248.93 kW
Total site energy5,000 kWh/day
Total grid energy imported5,000 kWh/day
Energy shifted1,301.92 kWh/day
Available flexible energy · before scheduling2,095.36 kWh/day
See the financial impact

Electricity imported from the grid

Representative day · 15-minute average power (kW)

Without optimizationLoad Shifting OnlyEffective capacity limit
Grid import and capacity by intervalPeak import is 429.96 kW before and 248.93 kW in the selected scenario. The effective capacity varies with entered temporary limits.012525037550000:0006:0012:0018:0024:00kW16:00–16:15Before: 426.91 kWSelected: 248.93 kWLimit: 350 kW
Site energy stays at 5,000 kWh/day. Grid imports 5,000 kWh/day.
View 15-minute data
Compare all four scenarios · same site inputs
ScenarioPeak (kW)Grid energy (kWh/day)Time over (min)Limits met
Without Optimization429.965,000180No
Load Shifting Only248.935,0000Yes
Battery Optimization Only324.155,026.270Yes
Combined Optimization238.355,013.140Yes

One synthetic day, not live grid data. Check any scenario against measured demand, site constraints and grid operator requirements before changing operations. The threshold check does not approve a connection.

Methodology, equations and validation

Energy Conservation. Power is an interval average in kW; energy is the sum of those values × 0.25 h in kWh. 1 MW = 1,000 kW and 1 MWh = 1,000 kWh. Load shifting changes timing, so daily site energy is conserved.

Physical Constraint Compliance and Critical Load Protection. The effective limit is the lowest active grid restriction or connection cap. Fixed demand stays at its original time. Flexible load can only move forward within its delay and allowed windows, within equipment power. A transfer or battery dispatch cannot create a new capacity violation or increase the original peak.

Data-Driven Optimization. A flow model allocates flexible energy between allowed intervals. Storage scheduling uses a reachable state-of-charge range. Each step seeks to reduce the largest exceedance first, then the peak, within numerical tolerance. Combined dispatch applies shifting and then storage, without claiming a globally optimal joint schedule.

Battery balance. Stored energy next interval = current stored energy + charging power × charging efficiency × 0.25 h − discharging power × 0.25 h ÷ discharging efficiency. Grid import = site load + charging − discharging. No export or simultaneous charge and discharge. The final charge equals the initial charge, so extra imported energy equals storage losses.

Transparent Financial Assumptions. Energy cost = ∑(grid import in kW × 0.25 h × the applied CHF/kWh tariff) × operating days. Demand cost = the highest billable kW in the month × the monthly CHF/kW rate, applied once. An unchanged peak on other days can limit the benefit. Net savings deduct recurring costs; simple ROI and payback use known upfront costs only.

Independent Technical Validation. Repeating a day misses seasonal peaks and operational variability. The demo does not forecast demand, model network power flow, or validate a dispatch on real equipment. A pilot would use permitted interval data and independent engineering review.

Grid operator economics is a separate future assessment: avoided congestion costs, deferred reinforcement, flexibility service value and participant payments. The calculator below estimates site bill effects only.

Battery modelling reference: REopt user manual

Financial simulator

Use the same electrical scenario.
Calculate its cost.

Apply your contract rates and implementation costs to the exact reference and selected grid import curves.

Linked scenario: Load Shifting Only · 248.93 kW peak · 5,000 kWh/day importedAdjust electricity inputs
YOUR TARIFF AND COST INPUTSExample rates
Tariff periods and implementation costs

The night rate applies outside the day period. Use identical rates for a flat tariff.

Leave unknown upfront costs blank. Enter zero only if that cost is known to be zero. Avoid counting battery wear twice.

Day rate: 07:00–22:00. These are adjustable inputs, not a supplier tariff or GridFlow quote.

MODELLED FINANCIAL IMPACTLinked model
Estimated annual net savingsCHF 25,423.94per year
Energy tariff savingsCHF 670.43per month
Peak demand charge savingsCHF 1,448.23per month
Implementation and operating costsCHF 0per month · deducted
Monthly cost before optimization
CHF 33,209.98
Monthly cost after, including running costs
CHF 31,091.32
Monthly billed peak, before → after
429.96 → 248.93 kW
Gross monthly savings
CHF 2,118.66
Gross annual savings
CHF 25,423.94
Net monthly savings
CHF 2,118.66

Enter known one-time costs to estimate ROI and payback.

One representative day is repeated for the entered operating days; other days’ energy costs are omitted on both sides. Twelve identical months do not capture seasons or exceptional peaks.

A model you can examine

A credible opportunity starts
with clear assumptions.

See the equations and limits in the simulator methodology. A pilot would test them on permitted site data with independent technical review.

“Load shifting preserves site energy in kWh. Battery losses are accounted for separately from the peak in kW.”

Energy stays accountable

“Model the electricity first. Apply the tariff to that same curve. Make every financial assumption visible.”

One scenario, connected calculations

“Protect critical operations, respect equipment limits and test schedules against real constraints with qualified professionals before deploying them.”

Operations come first
Questions, answered

Clear answers.
Before we begin.

Understand what is modelled today, what needs validation and how to start a pilot.

Still have a question? Let’s talk

GridFlow is developing decision support for electricity demand flexibility under limited grid capacity. The current simulator compares load shifting and battery schedules on representative data.

Your flexibility starts here

What could your site do
within its power limit?

We are seeking pilots to test peak shaving, load shifting and batteries on measured electricity profiles under agreed operating limits.

Your demand profile · Your operating constraints · Your business case